How many weep vents do you need, and what will they cost?
Fit one weep vent every 900mm along the damp-proof course and at least two over every window and door, no more than 450mm apart. For example, a two-storey semi with 22m of outside wall, 8 windows and 2 doors needs about 51 Active Weep Vents: £114 with free delivery. Every home is different, so enter your own measurements below.
Not sure what you need yet? Try the damp solution finder: a few quick questions, then a full plan.
Calculator
Example shown: a two-storey semi with 22m of outside wall, 8 windows and 2 doors. Change any answer to work out your own home.
Good fit
Active Weep Vents are designed for cavity walls. Each one fits a chased-out brick perpend joint.
Measure around the outside at damp-proof course level. Leave out walls shared with a neighbour.
Windows and doors in the outside walls
Total length of trays over bay windows, porch or lean-to roofs, conservatories and around chimneys. Vents go at 450mm centres, at least two per tray.
We multiply the count for one home by this number.
We recommend at least two in each frame. Wide frames can take more.
Your result
Active Weep Vents
51
| Along the damp-proof course(22m − 1.8m of door openings) ÷ 0.9m centres | 23 |
|---|---|
| Over windows8 × 3 each | 24 |
| Over external doors2 × 2 each | 4 |
- 1 × Whole House Pack (50), Natural
- 1 × Pack of 10, Natural
- Spare vents
- 9
- Vents
- £114
- UK mainland delivery
- Free
- Total, no VAT added
- £114
Pre-order. Free UK mainland delivery from £50. Fitting not included.
Active Trickle Vents
20
10 windows and doors × 2 each. Price on request; not yet orderable online.
Ask for a trickle vent priceThe spacing rules behind the number
- 1
Along the damp-proof course
One every 900mm, from Approved Document C (para 5.5(c) and Diagram 9b).
- 2
Over windows and doors
No more than 450mm apart, with at least two per opening (NHBC Standards, chapter 6.1). A 1.2m window takes three; a standard door takes two.
- 3
Other cavity trays
At 450mm centres, at least two per tray: over bays, porch and lean-to roofs, conservatories and around chimneys.
- 4
Upper floor levels
A further row at each floor level where the wall has cavity trays there.
- 5
Rising damp
About every 450mm along the affected wall for mild cases, or in every perpend (about 225mm) for most.
Not for tall residential buildings. Active Weep Vents are plastic. External wall materials must be Class A1 or A2-s1,d0 on buildings with homes and a storey 18m or more above ground (regulation 7(2), England and Wales), and on residential buildings with a storey more than 11m above ground (Approved Document B, Table 10.1, England; the law in Scotland). A fire-rated version is in development.
Weep vent prices at a glance
Packs of 10 for £24, the Whole House Pack of 50 for £90, and packs of 100 for £160. The table shows the cheapest way to buy common quantities.
| Vents needed | Cheapest packs | Vents | Delivery | Total | Per vent |
|---|---|---|---|---|---|
| 10 | 1 × Pack of 10 | £24 | £3.99 | £27.99 | £2.40 |
| 20 | 2 × Pack of 10 | £48 | £3.99 | £51.99 | £2.40 |
| 30 | 3 × Pack of 10 | £72 | Free | £72 | £2.40 |
| 40 | 1 × Whole House Pack (50) | £90 | Free | £90 | £1.80 |
| 50 | 1 × Whole House Pack (50) | £90 | Free | £90 | £1.80 |
| 60 | 1 × Whole House Pack (50) + 1 × Pack of 10 | £114 | Free | £114 | £1.90 |
| 70 | 1 × Whole House Pack (50) + 2 × Pack of 10 | £138 | Free | £138 | £1.97 |
| 80 | 1 × Pack of 100 | £160 | Free | £160 | £1.60 |
| 100 | 1 × Pack of 100 | £160 | Free | £160 | £1.60 |
| 120 | 1 × Pack of 100 + 2 × Pack of 10 | £208 | Free | £208 | £1.73 |
| 150 | 1 × Pack of 100 + 1 × Whole House Pack (50) | £250 | Free | £250 | £1.67 |
| 200 | 2 × Pack of 100 | £320 | Free | £320 | £1.60 |
| 300 | 3 × Pack of 100 | £480 | Free | £480 | £1.60 |
| 400 | 4 × Pack of 100 | £640 | Free | £640 | £1.60 |
1,000 or more vents? Trade buyers pay much less per vent, and we quote on smaller trade orders too: ask about trade pricing.
Weep vents, answered
How many weep vents do I need?
Count one every 900mm along the damp-proof course, plus at least two over every window and door, no more than 450mm apart. Add vents at 450mm centres along any other cavity trays, and a row at each upper floor level where the wall has cavity trays there. Because homes vary so much in size and number of windows, measure your own walls and use the calculator above.
How far apart should weep vents be?
Every 900mm along a damp-proof tray, under Approved Document C (para 5.5(c)). Over windows and doors, NHBC Standards set a maximum of 450mm apart with at least two per opening. For walls with rising damp, we suggest about every 450mm for mild cases or in every perpend joint, about 225mm, for most cases.
How much do Active Weep Vents cost?
From £1.60 to £2.40 per vent depending on pack size: pack of 10 for £24, the Whole House Pack (50) for £90 and a pack of 100 for £160. Crystal Clear costs 10p more per vent. No VAT is added. UK mainland delivery is £3.99, or free on orders from £50. For 500 or more vents, ask about trade pricing.
Can weep vents help with rising damp?
Yes. Every rising damp job we have fitted so far has dried out and stayed dry, with the vents doing the work on their own. They cross-ventilate the base of the wall, which dries it, and lower the humidity in the cavity, which breaks the cycle of water evaporating from the damp-proof course or a tray, condensing on cold surfaces such as wall ties and insulation, and running back down. They are fitted from outside in the mortar joints, with no chemicals, no wiring and no running costs. Fit them about every 450mm for mild cases, or in every perpend (about 225mm) for most. We are now running monitored trials, logging moisture, humidity and wall temperature, and will publish the results.
Do I need trickle vents as well?
Weep vents help the wall cavity; trickle vents help the rooms. If you see condensation on windows or mould on inside walls, add Active Trickle Vents: we recommend at least two in each window or door frame. Each fits a 16mm hole drilled through the frame, with an inside and an outside part that click together.
Can Active Weep Vents be used on tall buildings?
Not on tall residential buildings. The vents are plastic, and external wall materials must be Class A1 or A2-s1,d0 on any building with homes or residential rooms and a storey 18m or more above ground (Building Regulations regulation 7(2), England and Wales). The same applies to residential buildings with a storey more than 11m above ground under Approved Document B in England, and by law at 11m in Scotland. Use a non-combustible weep vent there. A fire-rated Active Weep Vent is in development.
How are Active Weep Vents fitted?
A brick perpend (the vertical mortar joint) is chased out and the vent, 10 × 65 × 100mm, is pushed into the slot. The removable insert (patent pending) then lets you check and clear the cavity behind it at any time. See the installation guide for the steps.
More detail: weep vents compared · installation guide · Active Trickle Vent · Awaab's Law hub for landlords
Sources
Every figure on this page, where it comes from, and when we last checked it.
- Approved Document C, para 5.5(c) and Diagram 9b: weep holes every 900mm along a damp-proof tray, and at least two weep holes above an opening. Read the source
- NHBC Standards, chapter 6.1: weep holes over openings no more than 450mm apart, with at least two per opening. Read the source
- GB average gas unit rate, Direct Debit, 1 October to 31 December 2026, including 5% VAT: 7.97 p/kWh. Ofgem, Energy price cap: standing charges and unit rates by region (checked 11 October 2026)
- Typical domestic consumption value (TDCV) for gas, used by Ofgem from 1 July 2026: 9500 kWh/year. Covers all gas use in a typical home, including hot water and cooking, not just space heating. Ofgem, Summary of changes to energy price cap 1 July to 30 September 2026 (revised 2026 TDCV) (checked 11 October 2026)
- Share of all heat lost through the walls in an uninsulated home. Measured for uninsulated homes. In an insulated home the share is different, so treat this as a starting point you can change. Energy Saving Trust, Cavity wall insulation (checked 11 October 2026)
- Increase in thermal conductivity of rock wool at 5% moisture by weight, compared with dry (laboratory test). A study of insulation in general, not of Active Vent. Hayrullin, Haibullina and Sinyavin, Transportation Research Procedia 63 (2022) (checked 11 October 2026)
- Natural gas, kWh (gross CV), Scope 1 (direct emissions from burning the gas): 0.18231 kg CO₂e/kWh. DESNZ, Greenhouse gas reporting: conversion factors 2026 (checked 11 October 2026)
- DPCs and cavity trays account for almost half of all superstructure defects; missing weep vents are among the issues listed. NHBC, Technical Extra, Issue 18 (July 2015) (checked 11 October 2026)
- Of 390 failed brick cavity homes surveyed by BRE, 79 (20%) failed because rubble at the base of the cavity stopped water escaping. BRE's 2015 survey for Constructing Excellence Wales. BRE for BEIS (Research Paper 2021/017), Waterproofing cavity walls to allow insulation in exposed areas, Appendix A, Table 11 (checked 11 October 2026)
Prices come from our shop and may change; see the shop for the latest. Results depend on the property, its condition and exposure, how it is heated and used, and the weather. See our data and claims disclaimer.
Buying for several homes or a whole site?
Trade buyers pay much less per vent than our online prices. Tell us about the job and we will price it.